GAS COOLERS

line

 

 

 

THERMO-ELECTRIC CHILLER/GAS COOLERS FOR GENERAL PURPOSE INSTALLATIONS
USING 5" HEAT EXCHANGERS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler.
MODEL
 
DESCRIPTION

MANUAL

520
 

One-pass Gas Cooler - 2.5 l/m
One controlled heat exchanger.

1
530
 

Two-pass Gas Cooler - 4 l/m
One ambient & one controlled heat exchanger

530

540
 

Two-pass Gas Cooler - 2x2.5 l/m
Two controlled heat exchangers - dual stream

540
560
 

Two-pass Gas Cooler - 5/lm
Two controlled heat exchangers - single streams

560
570
 

Four-pass Gas Cooler - 8 l/m
Two ambient/two controlled heat exchangers

570


THERMO-ELECTRIC CHILLER/GAS COOLERS FOR GENERAL PURPOSE INSTALLATIONS
USING 10" HEAT EXCHANGERS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler.
MODEL
 
DESCRIPTION

MANUAL

1040
 

One-pass Gas Cooler - 5 l/m
One controlled heat exchanger

1040
1050
 

Two-pass Gas Cooler - 8 l/m
One ambient & one controlled heat exchanger

1050
1060
 

Two-pass Gas Cooler - 8 l/m
Two controlled heat exchangers - single stream

1060
1080
 

Two-pass Gas Cooler - 2x4 l/m
Two controlled heat exchangers - dual stream

1080
1090
 

Four-pass Gas Cooler - 15 l/m
Two ambient/two controlled heat exchangers

1090

THERMO-ELECTRIC CHILLER/GAS COOLERS FOR ACID MIST APPLICATIONS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler.
MODEL
 
DESCRIPTION

MANUAL

595E
 

Freezer Chiller - 2.5 l/m
Complete assembly with outlet dew point of -30°C

595E

1085E
  Freezer Chiller - 5 l/m
Freezer assembly only with outlet dew point of -30C - for use with customer's existing gas cooler as a pre-cooler
1085E
1095E
  Freezer Chiller - 5 l/m
Complete assembly with outlet dew point of -30°C
1095E


THERMO-ELECTRIC CHILLER/GAS COOLERS FOR SMALL OEM INSTALLATIONS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler. Note - Customer to supply own power supply.
MODEL
 
DESCRIPTION

MANUAL

620
  One-pass Gas Cooler - 2.5 l/m
One controlled heat exchanger
620

630
  Two-pass Gas Cooler - 4 l/m
One ambient & one controlled heat exchanger
630
640
  Two-pass Gas Cooler - 2x2.5 l/m
Two controller heat exchangers

640

THERMO-ELECTRIC CHILLER/GAS COOLERS FOR HAZARDOUS AREA INSTALLATIONS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler.
MODEL
 
DESCRIPTION

MANUAL

3010
  One-pass Gas Cooler - 0-2 l/m
One ambient heat exchanger (Digital display not included on this Model)

3010
3020
  Two-pass Gas Cooler - 0-4 l/m
Two ambient heat exchangers (Digital display not included on this Model)

3020
3040
  One-pass Gas Cooler - 6 l/m
One controller heat exchanger

3040
3050
  Two-pass Gas Cooler - 8 l/m
One ambient & one controlled heat exchanger
3050
3080
  Two-pass Gas Cooler - 10 l/m
Two controlled heat exchangers

3080

VORTEX COOLED CHILLER/GAS COOLERS FOR HAZARDOUS AREA INSTALLATIONS

Flow rates based on ambient temperature of 77°F and 12% vol H2O. Higher ambient temperatures and/or H2O levels will decrease the efficiency of the gas cooler.
MODEL
 
DESCRIPTION

MANUAL

1140
  One-pass Gas Cooler - 5 l/m
One air controlled heat exchanger

1140
1160
  Two-pass Gas Cooler - 8 l/m
One ambient & one air controlled heat exchanger

1160
1190
  Two-pass Gas Cooler - 15 l/m
Two air controlled heat exchangers
1190

 

 

   